MY ACCOUNT | NEWSLETTER |

Validation of a biomechanical testing protocol of craniodorsal hip luxation in feline cadavers


Objectives: The aim of the study was to describe a biomechanical testing protocol to reproduce ex vivo craniodorsal hip luxation specific to the feline model. The authors also evaluated the biomechanical properties of an intact hip joint compared with the fixation strength of two different techniques of extra-articular hip stabilization.

Methods: Eighteen hip joints (femur and hemipelvis) were harvested from nine mature feline cadavers. CT was performed for each hip joint so that a biomechanical base specific to each joint morphotype could be created using computer-aided design. The biomechanical bases were then produced using a three-dimensional printer to secure the hip joints during testing. A total of 34 biomechanical compression tests were performed. Eighteen compression tests were performed in the control group, of which two fractured. The remaining 16 hip joints were then randomly assigned either to group A (hip joints stabilized with an extra-articular ultra-high molecular weight polyethylene (UHMWPE) implant secured by an interference screw [n = 8]) or to group B (hip joints stabilized with a UHMWPE iliofemoral suture [n = 8]).

Results: Mean ± SD yield, failure load and linear stiffness in the control group were 616 ± 168 N, 666 ± 158 N and 231 ± 50 N/mm, respectively. The relative fixation strength (% of intact joint) before hip luxation in groups A and B was 43.8% and 34.7%, respectively. No statistical difference was found between groups A and B for yield and failure load. However, the reoccurrence of craniodorsal hip luxation was higher in group B than in group A, in 5/8 and 0/8 tests, respectively. Moreover, in group A, the extra-articular UHMWPE implant induced caudodorsal hip luxation, reported as failure mode in 7/8 cases.

Conclusions and relevance: This modified biomechanical protocol for testing craniodorsal hip luxation in a feline model was validated as repeatable and with acceptable variance. The extra-articular UHMWPE implant stabilization technique proved to be more efficient in avoiding reoccurrence of craniodorsal hip luxation than UHMWPE iliofemoral suture.

Julien Letesson, Bastien Goin, Eric Viguier and Thibaut Cachon. " Validation of a biomechanical testing protocol of craniodorsal hip luxation in feline cadavers and comparison of two ultra-high molecular weight polyethylene materials used for extra-articular hip stabilization." Journal of Feline Medicine and Surgery. Volume 24, Issue 10. https://doi.org/10.1177/1098612X221114

Like1
Dislike0
  • Please enter a comment


Name *
Email address *
Comment *


* Required fields

Information on the processing of your personal data
We inform you that, in compliance with the provisions of current national and European regulations for the Protection of Personal Data and Services of the Information Society and Electronic Commerce, by sending us this form you are expressly giving your consent to Grupo Asís Biomedia , SL, (hereinafter, "ASIS GROUP") so that, as the person in charge, it may process your personal data in order to respond to your request for contact and information by electronic means.

Likewise, when you expressly consent, we will process your personal data to send you specialized information, newsletters, offers and exclusive promotions from GRUPO ASIS and related companies.

For the aforementioned purpose, GRUPO ASIS may transfer your data to other companies linked to GRUPO ASIS or to third party service providers for the management of electronic communications and other security services, even in cases where they are outside of the European Union, provided that they legally guarantee the adequate level of protection required by European regulations.

At any time you can withdraw the consent given and exercise the rights of access, rectification, deletion, portability of your data and limitation or opposition to its treatment by contacting GRUPO ASIS by sending an email to protecciondatos @ grupoasis.com, or by written communication to address at Centro Empresarial El Trovador, 8th floor, office I, Plaza Antonio Beltrán Martínez 1, 50002, Zaragoza (Spain), indicating in either case the Ref. Personal data and the right you exercise, as well as attaching a copy of your ID or replacement identification document.


I have read and accept the treatment of my data according to the informed purpose and according Legal notes and the Privacy Policy
I wish to receive commercial information from GRUPO ASIS and related companies



More news

Evaluation of 3D additively manufactured canine brain models for teaching veterinary neuroanatomy

Like0
Dislike0

Reasons for whole carcass condemnations of cattle in the United States and implications for producer education and veterinary intervention

Like0
Dislike0

A New Penn Vet Clinic Brings Support and Hope for Dogs with Retinal Disease

Like0
Dislike0

Seek Labs Maps Foot-and-Mouth Disease with BioSeeker™ to Advance Development of a Pan-Target, Programmable Therapeutic

Like0
Dislike0

Cooperation in regional innovation networks among small and medium enterprises: Case study of a veterinary pharmaceutical company in Jalisco, Mexico

Like0
Dislike0

Newsletter

 
 

News of interest

EVENTS

Copyright © 2025 - All Rights Reserved
ISSN 2768-198X

Top