MY ACCOUNT | NEWSLETTER |

Does Lung Function Imaging Modality Have a Dosimetric Impact On Functional Avoidance Treatment Planning: Assessment Using Prospective Clinical Trial Data


Purpose

Functional avoidance radiotherapy proposes to use functional imaging to design treatment plans that reduce doses to functional regions of lung. Prospective data has shown that reducing doses to functional lung results in reduced pulmonary toxicity. Various lung function imaging modalities have been proposed for functional avoidance; however, there have been no studies evaluating whether using different imaging modalities results in dosimetrically different functional avoidance plans. The purpose of this study was to quantify the differences in treatment plans as a function of lung function imaging modality.

Methods

25 lung cancer patients enrolled on a prospective trial underwent nuclear medicine SPECT ventilation/perfusion scans prior to radiotherapy. A functional perfusion (‘FuncPerf’) and ventilation (‘FuncVent’) contour was generated by selecting ≥75% perfusion/ventilation values. The similarity between the FuncVent and FuncPerf contours was calculated using DICE coefficients. 2 plans were generated for each patient: a FuncVent-based and FuncPerf-based functional avoidance plan. The differences in mean dose and V20Gy to the FuncVent/FuncPerf structure between the functional avoidance plans based on ventilation/perfusion were calculated (presented as mean [range]).

Results

The DICE correlation between FuncVent/FuncPerf contours was 0.51 (0.21- 0.76). The difference in mean dose and V20Gy to the FuncVent structure between the ventilation/perfusion functional avoidance plans were 0.2 Gy (-0.9-3.4 Gy) and 0.82% (-2.5%-12.4%), respectfully. The differences in mean dose and V20Gy to the FuncPerf structure were 0.6 Gy (-0.3-2.4 Gy) and 1.6% (-0.5%-7.7%), respectfully. There was weak correlation between ventilation/perfusion DICE scores and differences in FuncVent/FuncPerf dose differences (all correlations <0.16).

Conclusion

Our data showed that on average, selecting ventilation or perfusion for functional avoidance resulted in similar dosimetric distributions; however, for individual patients the differences could be significant. Our study uses prospective trial data to offer seminal guidance by underscoring the need to individually consider ventilation and perfusion for functional avoidance radiotherapy.


Authors: J Belardo, S Zhang, E Castillo, R Castillo, C Rusthoven, B Jones, M Miften, T Guerrero, I Grills, Y Chen

Source: https://scholarlyworks.beaumont.org/

Like0
Dislike0
  • Please enter a comment


Name *
Email address *
Comment *


* Required fields

Information on the processing of your personal data
We inform you that, in compliance with the provisions of current national and European regulations for the Protection of Personal Data and Services of the Information Society and Electronic Commerce, by sending us this form you are expressly giving your consent to Grupo Asís Biomedia , SL, (hereinafter, "ASIS GROUP") so that, as the person in charge, it may process your personal data in order to respond to your request for contact and information by electronic means.

Likewise, when you expressly consent, we will process your personal data to send you specialized information, newsletters, offers and exclusive promotions from GRUPO ASIS and related companies.

For the aforementioned purpose, GRUPO ASIS may transfer your data to other companies linked to GRUPO ASIS or to third party service providers for the management of electronic communications and other security services, even in cases where they are outside of the European Union, provided that they legally guarantee the adequate level of protection required by European regulations.

At any time you can withdraw the consent given and exercise the rights of access, rectification, deletion, portability of your data and limitation or opposition to its treatment by contacting GRUPO ASIS by sending an email to protecciondatos @ grupoasis.com, or by written communication to address at Centro Empresarial El Trovador, 8th floor, office I, Plaza Antonio Beltrán Martínez 1, 50002, Zaragoza (Spain), indicating in either case the Ref. Personal data and the right you exercise, as well as attaching a copy of your ID or replacement identification document.


I have read and accept the treatment of my data according to the informed purpose and according Legal notes and the Privacy Policy
I wish to receive commercial information from GRUPO ASIS and related companies



More news

One Committed and Caring NC State Veterinary Student, So Many Choices

Like0
Dislike0

Dentalis Earns 5 VOHC® Seals, Positioning for Global Expansion in Animal Health

Like0
Dislike0

Advancing the 3Rs: innovation, implementation, ethics and society

Like0
Dislike0

Automated Knowledge-Based Radiation Treatment Planning in Canine and Feline Nasal Tumors

Like0
Dislike0

New hope and compassionate care for animal patients in pain

Like0
Dislike0

Newsletter

 
 

News of interest

EVENTS

Copyright © 2025 - All Rights Reserved
ISSN 2768-198X

Top