MY ACCOUNT | NEWSLETTER |

The Agreement between Feline Pancreatic Lipase Immunoreactivity and DGGR-Lipase Assay in Cats-Preliminary Results

The study was carried out on 50 cats in which DGGR-lipase activity and fPLI were tested in the same blood sample


The colorimetric catalytic assay based on the use of 1,2-o-dilauryl-rac-glycero-3-glutaric acid-(6'-methylresorufin) (DGGR) ester as a substrate for pancreatic lipase activity is commonly used for the diagnosis of pancreatitis in dogs and cats. Even though the assay has generally been shown to yield consistent results with feline pancreatic lipase immunoreactivity (fPLI) assay, the agreement may vary between assays of different manufacturers. In this study, the chance-corrected agreement between a DGGR-lipase assay offered by one of the biggest providers of diagnostic solutions in Poland and fPLI assay was investigated.

The study was carried out on 50 cats in which DGGR-lipase activity and fPLI were tested in the same blood sample. The chance-corrected agreement was determined using Gwet's AC1 coefficient separately for the fPLI assay's cut-off values of >3.5 μg/L and >5.3 μg/L. The DGGR-lipase activity significantly positively correlated with fPLI (Rs = 0.665; CI 95%: 0.451, 0.807, p < 0.001). The chance-corrected agreement between the fPLI assay and DGGR-lipase assay differed considerably depending on the cut-off values of the DGGR-lipase assay.

When the cut-off value reported in the literature (>26 U/L) was used, it was poor to fair. It was moderate at the cut-off value recommended by the laboratory (>45 U/L), and good at the cut-off value recommended by the assay's manufacturer (>60 U/L). The highest agreement was obtained between the fPLI assay at the cut-off value of 3.5 μg/L and the DGGR-lipase assay at the cut-off value of 55 U/L (AC1 = 0.725; CI 95%: 0.537, 0.914) and between the fPLI assay at the cut-off value of 5.3 μg/L and the DGGR-lipase assay at the cut-off value of 70 U/L (AC1 = 0.749; CI 95%: 0.577, 0.921).

The study confirms that the chance-corrected agreement between the two assays is good. Prospective studies comparing both assays to a diagnostic gold standard are needed to determine which of them is more accurate.

“The Agreement between Feline Pancreatic Lipase Immunoreactivity and DGGR-Lipase Assay in Cats-Preliminary Results” Magdalena Maria Krasztel, et al. Animals (Basel). 2021 Nov 6;11(11):3172. doi: 10.3390/ani11113172.

Like1
Dislike0
  • Please enter a comment


Name *
Email address *
Comment *


* Required fields

Information on the processing of your personal data
We inform you that, in compliance with the provisions of current national and European regulations for the Protection of Personal Data and Services of the Information Society and Electronic Commerce, by sending us this form you are expressly giving your consent to Grupo Asís Biomedia , SL, (hereinafter, "ASIS GROUP") so that, as the person in charge, it may process your personal data in order to respond to your request for contact and information by electronic means.

Likewise, when you expressly consent, we will process your personal data to send you specialized information, newsletters, offers and exclusive promotions from GRUPO ASIS and related companies.

For the aforementioned purpose, GRUPO ASIS may transfer your data to other companies linked to GRUPO ASIS or to third party service providers for the management of electronic communications and other security services, even in cases where they are outside of the European Union, provided that they legally guarantee the adequate level of protection required by European regulations.

At any time you can withdraw the consent given and exercise the rights of access, rectification, deletion, portability of your data and limitation or opposition to its treatment by contacting GRUPO ASIS by sending an email to protecciondatos @ grupoasis.com, or by written communication to address at Centro Empresarial El Trovador, 8th floor, office I, Plaza Antonio Beltrán Martínez 1, 50002, Zaragoza (Spain), indicating in either case the Ref. Personal data and the right you exercise, as well as attaching a copy of your ID or replacement identification document.


I have read and accept the treatment of my data according to the informed purpose and according Legal notes and the Privacy Policy
I wish to receive commercial information from GRUPO ASIS and related companies



More news

Advancing the 3Rs: innovation, implementation, ethics and society

Like0
Dislike0

Automated Knowledge-Based Radiation Treatment Planning in Canine and Feline Nasal Tumors

Like0
Dislike0

Does Lung Function Imaging Modality Have a Dosimetric Impact On Functional Avoidance Treatment Planning: Assessment Using Prospective Clinical Trial Data

Like0
Dislike0

One Committed and Caring NC State Veterinary Student, So Many Choices

Like1
Dislike0

Dentalis Earns 5 VOHC® Seals, Positioning for Global Expansion in Animal Health

Like0
Dislike0

Newsletter

 
 

News of interest

EVENTS

Copyright © 2025 - All Rights Reserved
ISSN 2768-198X

Top